    Neumann MA 1 Measurement Microphone

    Notify me when this product is available:

    Neumann’s Automatic Monitor Alignment MA 1 ensures the best possible sound quality in any room – from home studios to professional control rooms. Using the individually calibrated measurement microphone your acoustic environment is analyzed in a guided process. Advanced calibration algorithms, jointly developed with the world's leading institute in audio processing, Fraunhofer IIS, guarantee an optimally adapted amplitude and phase correction for exact and reliable monitoring.

    RELIABLE MONITORING ANYWHERE

    Neumann’s Automatic Alignment is a dedicated tool for stereo sets of KH 80 DSP monitors with or without the KH 750 DSP as well as two non-DSP-based KH-Line monitors connected to the analog outputs of a KH 750 DSP subwoofer. Unlike conventional correction software, it is an integrated solution with novel algorithms, jointly developed with the Fraunhofer Institute for Integrated Circuits (IIS) specifically for Neumann studio monitors. No plug-in or special audio driver is required: Alignment data is stored and processed within the DSP-powered monitors themselves. As a unique benefit, the software not only optimizes the amplitude response but also optimizes the phase. This provides the highest accuracy in terms of tonality and impulse reproduction.

    HOW IT WORKS

    In the first step, acoustic data of the listening environment is gathered in a guided process. No special acoustic knowledge is required. Simply connect your Neumann monitors to the outputs of your audio interface or monitor controller. Additionally, your DSP-based KH-line monitors must also be connected to your computer’s ethernet port. For multiple connections, a standard ethernet switch will do. Now plug the measurement microphone into your microphone input. This microphone was specifically developed for this software and is individually calibrated by it. The software will guide you through the measurement process. From the measured data, the software ascertains the room’s acoustic properties. The individual correction parameters are generated according to a room-specific target curve calculated by the software. Neumann's decades of experience in calibrating monitoring systems in studio control rooms have been incorporated into this process. Of course, you can modify the target curve to your needs. Additionally, the alignment process ensures an optimal summation in the low frequencies when a subwoofer is used. All resulting correction parameters are stored and processed in the DSP-powered monitors. So there is nothing to worry about anymore, no plug-ins, no driver issues. And no additional cables, either: Once the alignment process is completed, the ethernet connections are not required anymore.

    Using the KH 750 DSP subwoofer, stereo sets of analog KH-Line monitors, too, can be used with the Automatic Monitor Alignment Software. The KH 750 DSP has enough processing power to align the entire system including the two analog loudspeakers connected to its outputs. Additionally, KH 120, KH 310, and KH 420 loudspeakers profit from phase linearization of their built-in crossover filters! The result is increased clarity, a dry bass, and a time-correct, more accurate depiction of reverbs and acoustic spaces. For the market launch, we are offering attractive kits consisting of KH Line Monitors and the MA 1 package (see order info).

    THE FUTURE

    The MA 1 Automatic Monitor Alignment is the beginning of a new era in monitoring. Starting with the current version, which delivers outstanding acoustic results for stereo setups, the range of software functions will be expanded step by step with updates.

    Features:

    • Calibration algorithms jointly developed with Fraunhofer IIS

    • For stereo setups with KH 80 DSP and all pairs of analog (non-DSP-based) Neumann monitors using the KH 750 DSP subwoofer

    • Individually calibrated measurement microphone

    • Room adaptive target curve

    • Phase and amplitude optimization for analog Neumann monitors

    • For Mac and PC

     

    Specifications:


    HARDWARE REQUIREMENTS

    • 1 pair of KH DSP loudspeakers or 1 KH 750 DSP subwoofer in combination with a pair of analog (non-DSP based) KH loudspeakers

    • Neumann MA 1 measurement microphone

    • Computer (Windows 10 64 Bit and macOS 10.13, 10.14, or 10.15)

    • Audio interface with balanced analog input with 48 V phantom power and 2 balanced analog outputs or digital AES3 output (only with KH 750 DSP)

    • Network switch

    • Screen resolution of 1280×720 px or higher

    SOFTWARE REQUIREMENTS

    • Operating system: Windows 10 64 Bit and macOS 10.13, 10.14 or 10.15

    • Neumann Automatic Monitor Alignment software

    • ASIO driver (for Windows)

    DSP LOUDSPEAKERS (NETWORK-ENABLED)

    The following loudspeakers and subwoofers are network-enabled and can be controlled directly by the software:

    • KH 80 DSP

    • KH 750 DSP

    ANALOG LOUDSPEAKERS (NOT NETWORK-ENABLED)

    The following loudspeakers are not network-enabled and need to be connected via a network-

    enabled subwoofer in order to be included in the system setup.

    • KH 120 A

    • KH 120 D

    • KH 310 A

    • KH 310 D

    • KH 420/KH 420 + DIM 1