By design, the CCM 4 was optimised for rejection of rear-incident sound. As is typical of a classic cardioid, the attenuation at 90° incidence angle is 6 dB and at 180° it reaches 20-30 dB. Diffuse sound is reduced by 4.8 dB compared to frontally-incident sound – a value corresponding to the directivity index. The higher this value is, the less room sound the microphone picks up, thus lowering the risk of acoustic feedback.
Thanks to its directivity, the CCM 4 can achieve the same diffuse-to-direct sound balance from 1.7 times the distance to the sound source compared to a pure pressure transducer with the same sensitivity.